• info@sentinelgroup.mv

DRY RISER SYSTEM

Dry fire main water supply pipe installed in a building for fire-fighting purposes, fitted with inlet connections at fire service access level and landing valves at specified points, which is normally dry but is capable of being charged with water usually by pumping from fire and rescue service appliances.


WET RISER SYSTEM

Wet fire main water supply pipe installed in a building for firefighting purposes and permanently charged with water from a pressurized supply, and fitted with landing valves at specified points. Where fire mains are installed and there are no floors higher than 50 m above fire service access level, wet or dry fire mains may be installed.


HOSE REEL SYSTEM

Fire hose reel systems consist of pumps, pipes, water supply and hose reels located strategically in a building, ensuring proper coverage of water to combat a fire. The system is manually operated and activated by opening a valve enabling the water to flow into the hose that is typically 30 meters away.


WATER DRENCHER SYSTEM FOR FUEL AND GAS TANKS

These systems are used for fire protection of technologies and objects where it is possible to use water as the extinguishing agent. They are intended mainly for extinguishing, cooling down, preventing the radiant heat from spreading, cooling down surfaces of buildings, steel structures and technological equipment.


HYDRANT SYSTEM

The fire hydrant system is the backbone of the firefighting systems in a building or premises. The system is a water distribution system consisting of water tank, suction piping, fire pumps and a distributed piping system. The distributed piping system establishes connectivity throughout the building or premises through fire hydrants, hoses and nozzles.


SPRINKLER SYSTEM

Automatic fire sprinkler systems also known as a wet pipe system are widely regarded as the most effective method of controlling fires caused by a broad range of hazards. With experience, WE offer end-to-end fire sprinkler systems to protect your people, business and assets


FIRE ALARM SYSTEM

Fire detection systems are designed to discover fires early in their development when me will still be available for the safe evacuation of occupants. Property loss can be reduced and downtime for the operation minimized through early detection because control efforts are started while the fire is still small.


CO2 SUPPRESSION/FLOODING SYSTEM

Carbon dioxide suppresses fire without leaving behind any residues after discharge thus avoiding damage to sensitive equipment. With no agent clean up, there is less downtime after an incident. When properly designed, the carbon dioxide system will suppress fire in Class A, B, and C hazards by displacing the air containing oxygen that supports combustion.


FM200 system

FM-200 has established itself as one of the most popular clean fire suppression agents. This is due to its ability to quickly knock down Class A, B and C fires with no risk of thermal shock damage to delicate equipment. FM-200 is electrically non-conductive and non-corrosive; it leaves no residue.


FOAM POURING System

Commonly protect any areas that involve the storage, processing or transportation of flammable liquids and include Bladder Tanks and Fixed Foam Skids. The principle of a Foam Proportioning Systems is to produce Low, Medium or High Expansion Foam to smother or blanket an area of combustion or potential risk.


Kitchen HOOD SUPPRESSION / WET CHEMICAL System

Wet chemical suppression system is used to protect modern commercial kitchen from potential threats like open flame, red hot cooking surface and heavily grease laden environment which in turn leads to oil and grease fires.


FIRE PUMPS & ACCESSORIES

Fire pumps are essential components of a building's fire protection system, especially in high-rise structures. In buildings with levels from 400-500 ft. and higher, fire pumps are critical in distributing water through sprinkler systems where water pressure from water mains and fire fighting equipment cannot reach. Even in lower set buildings, a fire pump is key to containing a fire. Firefighting, at its best, is a hazardous business, but without a well-designed and professionally installed system and pump it becomes even more dangerous, and business assets and lives are put at greater risk. A fire pump is critical fire and life-safety equipment in many buildings. There are numerous requirements and elements to be considered prior to the installation of any unit. The building owner, architect, engineer, local fire marshal, and the fire protection provider should all participate in the discussion for the pump and system to ensure a well-planned and compliant final installation.



FIRE EXTINGUISHER

Fire extinguishers are extremely important as they are the most used for of fire protection. In many cases they are the first line of defense and often contain or extinguish a fire, preventing costly damage. These often overlooked devices can be a key component towards keeping you safe during a fire emergency. Business owners sometimes view fire extinguishers as red cans simply hanging on the wall and expense to managing their business. But these red cans serve a very useful purpose. The fact remains that in more than 600 businesses and non-residential structures, fire extinguishers are the difference between a minor fire problem and destruction. According to the National Fire Protection Association (NFPA), fires can be diminished using a fire extinguisher. For apartment buildings and medical centers, the presence of a fire extinguisher can provide incredible benefits. The mere presence of a fire extinguisher can have a significant impact on diminishing the damage caused by a fire.


SAFETY GEAR

Firefighters perform diverse tasks like firefighting, aircraft fires & other vehicle fires, wildland firefighting etc. Firefighters garments should be designed considering some functions, the most important of which is protection against heat & flame. And protection against moisture is also important depending on the type of extinguishing method.


MODULAR FIRE EXTINGUISHERS

For Round, clock protection, for unmanned areas. Doesn't Require cumbersome piping, is easy to install, and is available in Dry powder and Clean Agent Variants. Modular Fire Extinguishers are fitted with an automatic sprinkler valve, that can be calibrated to discharge at an ambient temperature of 57C. 68C, 79C, and 93C. They don't depend on an external source of energy and can be operated electrically or mechanically for their operation.


SUPER FIRE BALL

Super Fire Ball is the easiest and fastest fire extinguisher to interfere the local fires. This Fabolous devise is unpressurised container made with polystyrene. It contains Dry Chemical Powder that has been developed from Boron Mineral and micronized specifically for Super Fire Ball. This Activation Mechanism works with the fuse detection (which allows the ball to function within 1-5 seconds).